Category: APC Surge Protection

AP8881

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.


Business IT purchase over £1000? Spread the cost on a monthly basis with our flexible leasing options.

Technical Information

Certification
CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Colour of product
Black
Product colour
Black
Certification
CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Mounting
Vertical
Rack capacity
0U
Colour of product
Black
Mounting
Vertical
PDU types
Metered
Rack capacity
0U
PDU types
Metered
Nominal output voltage
230 V
Nominal input voltage
400 V
Maximum total current draw per phase
16 A
Maximum input current per phase
16 A
Maximum current
16 A
Load capacity
11040 VA
Maximum power
11000 W
Nominal output voltage
230 V
Nominal input voltage
400 V
Maximum total current draw per phase
16 A
AC input frequency
50 - 60 Hz
Maximum input current per phase
16 A
Input frequency
50/60
Maximum current
16 A
Load capacity
11040 VA
Maximum power
11040 W
AC input frequency
50 - 60 Hz
Cable length
1.83 m
Certification
CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Cable length
1.83 m
Certification
CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Cable length
1.83 m
Nominal input voltage
400 V
Maximum input current per phase
16 A
Input frequency
50/60
Maximum current
16 A
Power plug
IEC309
Monitoring
Current, Power, Voltage
Monitoring
Current, Power, Voltage
Operating relative humidity (H-H)
5 - 95%
Storage temperature (T-T)
-25 - 65 °C
Operating temperature (T-T)
5 - 45 °C
Storage relative humidity (H-H)
5 - 95%
Operating relative humidity range
5 - 95%
Storage temperature range (T-T)
-25 - 65 °C
Operating temperature range (T-T)
5 - 45 °C
Storage relative humidity range
5 - 95%
Source data-sheet
ICEcat.biz
Nominal output voltage
230 V
AC outlets quantity
42 AC outlet(s)
AC outlet types
C13 coupler, C19 coupler
Output connections
36x IEC 320 C13 6x IEC 320 C19
Input connection type
IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
AC outlets quantity
42 AC outlet(s)
Power plug
IEC309
Output connections
36x IEC 320 C13 6x IEC 320 C19
Input connection type
IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
AC outlet types
C13 coupler, C19 coupler
AC outlets quantity
42 AC outlet(s)
Power plug
IEC309
AC outlet types
C13 coupler, C19 coupler
Cable length
1.83 m
Output connections
36x IEC 320 C13 6x IEC 320 C19
Input connection type
IEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
Source data-sheet
ICEcat.biz
PDU types
Metered
Dimensions (WxDxH)
56 x 44 x 1791 mm
Weight
6.38 kg
Dimensions (WxDxH)
56 x 44 x 1791 mm
Weight
6.38 kg